﻿{"id":5716,"date":"2025-05-03T21:14:52","date_gmt":"2025-05-03T13:14:52","guid":{"rendered":"https:\/\/profixtips.com\/product\/2kt_ol_protector\/"},"modified":"2025-05-10T12:19:08","modified_gmt":"2025-05-10T04:19:08","slug":"2kt_ol_protector","status":"publish","type":"product","link":"https:\/\/profixtips.com\/cs\/product\/2kt_ol_protector\/","title":{"rendered":"2ks \/Balen\u00ed 1,1.5,2,3HP Ochrana proti p\u0159et\u00ed\u017een\u00ed kompresoru klimatizace\/odvlh\u010dova\u010de"},"content":{"rendered":"<p>Title: 2x \/Lot 1,1.5,2,3 HP Air Conditioner Dehumidifier Compressor Overload Protector<\/p>\n<p><!--PA4_HTMLTop_End--><\/p>\n<div><strong>Universal 1HP,1.5HP,2HP,3HP Air Conditioner Dehumidifier Compressor Motor Overload Protector Repair Units<\/strong><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><strong>Jak zkontrolovat, zda tepeln\u00e1 ochrana kompresoru funguje spr\u00e1vn\u011b?\u00a0<\/strong><\/div>\n<div><\/div>\n<div>Check\u00a0It\u00a0With\u00a0Multifunction\u00a0Meter\uff0cIF\u00a0The\u00a0Resistance\u00a0is\u00a0Below 1\u00a0\u03a9 (0 \u03a9)\uff0cIt\u2019s\u00a0OK; If it is\u00a0\u221e, It is\u00a0Damaged.<\/div>\n<div><\/div>\n<div><\/div>\n<div>1.Air Conditioner \/ Dehumidifier \/ Refrigerator Overload Protector attaches to the compressor and shuts off the compressor if the compressor motor draws too much current.<\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\">2.N\u00edzk\u00fd profil a n\u00edzk\u00e1 hmotnost, vysoce spolehliv\u00fd v\u00fdkon. Ide\u00e1ln\u00ed pro kompresor klimatizace nebo jin\u00e9 elektrick\u00e9 ochrann\u00e9 za\u0159\u00edzen\u00ed.<\/div>\n<div><\/div>\n<div>3.Bezpe\u010dn\u011b uskladn\u011bte v\u0161echny potraviny, kter\u00e9 by se mohly zkazit p\u0159i v\u00fdpadku proudu, a p\u0159ed instalac\u00ed tohoto d\u00edlu odpojte chladni\u010dku od s\u00edt\u011b. Pou\u017e\u00edvejte pracovn\u00ed rukavice k ochran\u011b rukou.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><strong>Specifikace:<\/strong><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\">\n<p>For:1- 3 HP(Compressor Motor\u2019s Rate Of Power) Air Conditioner Compatible<\/p>\n<div><\/div>\n<\/div>\n<div><\/div>\n<div>\n<div id=\"pastingspan1\">\u2013Vyrobeno z bimetalov\u00e9ho materi\u00e1lu<\/div>\n<div><\/div>\n<div><\/div>\n<p><span style=\"background-color: yellow;\">HP = Ko\u0148sk\u00e1 s\u00edla = 735,49875 Watt\u016f<\/span><\/p>\n<\/div>\n<div><\/div>\n<div id=\"pastingspan1\">Total Size: 2.6 x 2.8 cm \/ 1\u2033 x 1.1\u201d(D*H) , Pin\u2019s\u00a0Width\uff1aAbout 6.5mm<\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><strong>Balen\u00ed obsahuje:<\/strong><\/div>\n<div><\/div>\n<div>2x\/Lot\u00a0 Air Conditioner Thermal Overload Protector<\/div>\n<div>\u2014-( N\u00e1hodn\u00e1 barva\/typ bude odesl\u00e1n jako v\u00fdchoz\u00ed )<\/div>\n<div><\/div>\n<div><strong style=\"font-family: Verdana; color: red;\">We Have the 1 HP, 1.5 HP, 2 HP, 3 HP Overload Protectors For\u00a0Choosing\uff01<\/strong><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div>\u00a0<span style=\"font-family: 'Work Sans', Arial, sans-serif; font-size: 20px; background-color: #ffffff;\"><strong>Co je to \u2018tepeln\u00e1 ochrana\u2019 u elektromotoru?<\/strong><\/span><\/div>\n<div>\n<div id=\"pastingspan1\">Kdy\u017e se v popisu elektromotoru setk\u00e1te s pojmem \u201ctepeln\u00e1 ochrana\u201d nebo \u201ctepeln\u011b chr\u00e1n\u011bn\u00fd\u201d, jedn\u00e1 se o za\u0159\u00edzen\u00ed um\u00edst\u011bn\u00e9 uvnit\u0159 motoru nebo motorov\u00e9ho kompresoru, kter\u00e9 je navr\u017eeno tak, aby zabr\u00e1nilo nebezpe\u010dn\u00e9mu p\u0159eh\u0159\u00e1t\u00ed, je\u017e by mohlo zp\u016fsobit selh\u00e1n\u00ed motoru.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><strong>\u00da\u010del tepeln\u00e9ho ochrann\u00e9ho prvku<\/strong><\/div>\n<div><\/div>\n<div id=\"pastingspan1\">K tomuto p\u0159eh\u0159\u00e1t\u00ed obvykle doch\u00e1z\u00ed p\u0159i p\u0159et\u00ed\u017een\u00ed motoru, p\u0159i zablokov\u00e1n\u00ed lo\u017eiska, p\u0159i zablokov\u00e1n\u00ed h\u0159\u00eddele motoru, kter\u00e9 br\u00e1n\u00ed jeho ot\u00e1\u010den\u00ed, nebo kdy\u017e motor jednodu\u0161e nenastartuje spr\u00e1vn\u011b. Selh\u00e1n\u00ed startu m\u016f\u017ee b\u00fdt zp\u016fsobeno vadn\u00fdmi startovac\u00edmi vinut\u00edmi v motoru.<\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\">Tepeln\u00fd ochrann\u00fd prvek se skl\u00e1d\u00e1 z jednoho nebo v\u00edce teplotn\u011b citliv\u00fdch prvk\u016f zabudovan\u00fdch do motoru nebo motor-kompresoru a z extern\u00edho \u0159\u00eddic\u00edho za\u0159\u00edzen\u00ed. Tepeln\u00e1 ochrana slou\u017e\u00ed k vypnut\u00ed motoru, kdy\u017e je v obvodech motoru generov\u00e1no nadm\u011brn\u00e9 teplo, \u010d\u00edm\u017e zastav\u00ed n\u00e1r\u016fst teploty d\u0159\u00edve, ne\u017e by mohlo doj\u00edt ke sp\u00e1len\u00ed motoru.<\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\">Tyto tepeln\u00e9 ochrann\u00e9 prvky se samy resetuj\u00ed, jakmile motor vychladne na bezpe\u010dnou provozn\u00ed teplotu. Na stran\u011b motoru s kabel\u00e1\u017e\u00ed je obvykle viditeln\u00e9 \u010derven\u00e9 tla\u010d\u00edtko \u2013 obvykle, i kdy\u017e ne v\u017edy, um\u00edst\u011bn\u00e9 na opa\u010dn\u00e9 stran\u011b, ne\u017e je h\u0159\u00eddel motoru. U motor\u016f vy.<\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\">Having a motor shut down because it tripped a thermal limit is inconvenient, but it certainly is better than having to replace a motor because it overheats. And the shut-down can alert you to problems with the motor or connected devices, or to the load attached to the motor. When a motor fails to start or overheats during operation, it may indicate that the motor has reached the end of its useful life and must be replaced. But often the fault does not lie with the motor at all. There could be an obstruction on the load attached to the motor, leading to excessive load that causes heat to build up in the motor\u2014tripping the thermal protector that saves the motor.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><strong>Examples of Motors With Thermal Protectors<\/strong><\/div>\n<div><\/div>\n<div id=\"pastingspan1\">A sump pump is a motor for which this scenario often occurs. If a sump pump pumps water filled with debris, pieces of debris may get caught in the impeller and lock the rotation of the pump motor, causing it to overheat very quickly. On a pump equipped with thermal protection, the device will trip and shut down the circuit to the motor windings. This will allow the motor to cool down and may well save it from complete failure. Alerted to the problem because the motor shuts down, you may be able to clear the impeller and keep your sump pump motor operating for quite some before it needs replacing.<\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\">The same scenario may be true on other electric motors that process variable loads, such as garbage disposers, washing machines or vacuum cleaners. Without thermal protection, such motors can be more prone to burn-out.<\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\">\u201cThermal protection\u201d is generally a good feature to look for when buying equipment with electrical motors. By protecting the motor from overheating, it can greatly extend the life of the motor.<\/div>\n<\/div>\n<div><\/div>\n<div>\n<div id=\"pastingspan1\"><strong style=\"color: red;\">Refrigerator \/ Air Conditioner \/ Dehumidifier compressor overheating Protector action and downtime of its fault causes and treatment methods:<\/strong><\/div>\n<div><\/div>\n<div id=\"pastingspan1\">(1) Too much refrigerant, too little, will cause the compressor overload heat, vacuum from the new addition of refrigerant, complement the refrigerant can be done.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\">(2) The capillary or cloth filter blockage, resulting in too high suction temperature; Check capillary or dry filter, replace a capillary or dry filter of the same specification.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\">(3) Condenser inlet and outlet blockage, resulting in excessive condensation pressure, compressor overload and downtime: should remove obstacles at the inlet and outlet.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\">(4) Condenser ash is too thick, condensation pressure is too high: cleaning condenser on the ash accumulation.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\">(5) Compressor overload protector failure: Test the current of the compressor. The cause of the over-current is detected, and the overload protector can also be replaced directly.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\">(6) Compressor motor coil short circuit, heat: replace the motor coil.<\/div>\n<div><\/div>\n<div id=\"pastingspan1\">(7) The compressor power supply voltage is unstable. Causing the operating current to be too large, so that the overheating Protector action: configurable regulator.<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>2x \/Lot 1HP,1.5HP,2HP,3HP Air Conditioner Dehumidifier Compressor Motor Overload Protector<\/p>","protected":false},"featured_media":5717,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[2],"product_tag":[28],"class_list":["post-5716","product","type-product","status-publish","has-post-thumbnail","product_cat-air-conditioner-parts","product_tag-air-conditioner-parts","product_shipping_class-free-shipping","first","instock","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/product\/5716","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/comments?post=5716"}],"version-history":[{"count":0,"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/product\/5716\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/media\/5717"}],"wp:attachment":[{"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/media?parent=5716"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/product_brand?post=5716"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/product_cat?post=5716"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/profixtips.com\/cs\/wp-json\/wp\/v2\/product_tag?post=5716"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}