﻿{"id":2230,"date":"2025-05-03T19:39:02","date_gmt":"2025-05-03T11:39:02","guid":{"rendered":"https:\/\/profixtips.com\/product\/ac-contactor\/"},"modified":"2025-06-02T02:07:07","modified_gmt":"2025-06-01T18:07:07","slug":"air-conditioner-ac-contactor","status":"publish","type":"product","link":"https:\/\/profixtips.com\/es\/product\/air-conditioner-ac-contactor\/","title":{"rendered":"Contacto de rel\u00e9 para aire acondicionado HVAC universal de 1 o 2 polos, 25A 100-220V, bobina"},"content":{"rendered":"<h1 style=\"font-size: 24px;\">Contacto de rel\u00e9 para aire acondicionado HVAC universal de 1 o 2 polos, 25A 100-220V, bobina<\/h1>\n<div>\n<figure id=\"attachment_2234\" aria-describedby=\"caption-attachment-2234\" style=\"width: 600px\" class=\"wp-caption alignleft\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2234 size-bricks_medium\" src=\"https:\/\/profixtips.com\/wp-content\/uploads\/2025\/05\/AC-Contactor-3-600x446.jpg\" alt=\"AC-Contactor Specifications\" width=\"600\" height=\"446\" srcset=\"https:\/\/profixtips.com\/wp-content\/uploads\/2025\/05\/AC-Contactor-3-600x446.jpg 600w, https:\/\/profixtips.com\/wp-content\/uploads\/2025\/05\/AC-Contactor-3-300x223.jpg 300w, https:\/\/profixtips.com\/wp-content\/uploads\/2025\/05\/AC-Contactor-3-1024x760.jpg 1024w, https:\/\/profixtips.com\/wp-content\/uploads\/2025\/05\/AC-Contactor-3-768x570.jpg 768w, https:\/\/profixtips.com\/wp-content\/uploads\/2025\/05\/AC-Contactor-3-1536x1140.jpg 1536w, https:\/\/profixtips.com\/wp-content\/uploads\/2025\/05\/AC-Contactor-3-1200x891.jpg 1200w, https:\/\/profixtips.com\/wp-content\/uploads\/2025\/05\/AC-Contactor-3.jpg 1600w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><figcaption id=\"caption-attachment-2234\" class=\"wp-caption-text\">AC-Contactor Specifications<\/figcaption><\/figure>\n<\/div>\n<div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">What&#8217;s the AC contactor?<\/span><\/strong><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">1. The AC contactor is an automatic controller that uses electromagnetic suction to make and disconnect the circuit. It is mainly composed of an iron core, a coil, and a contact. The AC contactor controls the start and stop of the compressor.<\/span><\/p>\n<p><strong><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">2. Fault phenomenon: the press does not start and does not work<\/span><\/strong><\/p>\n<p><strong><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">3. Detection method:<\/span><\/strong><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">1. Detect the resistance of the coil winding to see if it is disconnected or short-circuited;<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">2. Use the ohm gear of the multimeter to detect the on-off status of the upper and lower contacts of the AC contactor.\u00a0<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">The resistance value of the upper and lower contacts should be infinite when the power is not turned on. If there is a resistance value, it indicates that the internal contacts are stuck;<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">3. Press the forced button on the surface of the AC contactor, and use a multimeter to measure the resistance of the upper and lower contacts.\u00a0<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">The resistance of each group should be zero under normal circumstances.\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">If it is infinite or the resistance increases, it indicates that the internal contact surface may have Arc phenomenon.\u00a0<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">If the above three phenomena occur, the AC contactor should be replaced;<\/span><\/p>\n<p><strong><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">4. Notes:<\/span><\/strong><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">For single-phase 3-horse air conditioners, the AC contactor is easily damaged when the voltage is unstable or the voltage drop during startup is large.\u00a0<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">will cause the above failures.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">MPN:CJX9B\/25SD CJX9B\/25S<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">1Pole : CJX9B\/25S<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">2Pole : CJX9B\/25SD<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">CJX9B-25S\/D AC contactors are generally used to control the single-phase loaded circuit systems, which are of AC 50\/60Hz, rated coil voltage up to AC 220-240V and rated \u00a0thermal current up to 32A.\u00a0<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">They are extensively applied to control the main circuit of single-phase mechanical devices and the compressors of single-phase air conditioners.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">Confirme en las especificaciones del listado si este art\u00edculo ser\u00e1 compatible con su dispositivo antes de realizar el pedido.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">Si tiene alguna consulta o pregunta, no dude en contactarnos antes de comprar. \u00a1Gracias!<\/span><\/p>\n<p><strong><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14pt;\">Paquete Incluye:<\/span><\/strong><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">1x AC Contactor<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">\u2014- (Se enviar\u00e1 lote\/color\/tipo aleatorio por defecto)<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Contacto de rel\u00e9 para aire acondicionado HVAC universal de 1 o 2 polos, 25A 100-220V, bobina<\/p>","protected":false},"featured_media":2231,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[2],"product_tag":[28],"class_list":["post-2230","product","type-product","status-publish","has-post-thumbnail","product_cat-air-conditioner-parts","product_tag-air-conditioner-parts","product_shipping_class-free-shipping","first","instock","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/product\/2230","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/comments?post=2230"}],"version-history":[{"count":0,"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/product\/2230\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/media\/2231"}],"wp:attachment":[{"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/media?parent=2230"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/product_brand?post=2230"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/product_cat?post=2230"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/profixtips.com\/es\/wp-json\/wp\/v2\/product_tag?post=2230"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}