﻿{"id":1311,"date":"2025-05-03T19:24:25","date_gmt":"2025-05-03T11:24:25","guid":{"rendered":"https:\/\/profixtips.com\/product\/midea-kt-sensor-10k-kit\/"},"modified":"2025-06-04T03:49:04","modified_gmt":"2025-06-03T19:49:04","slug":"midea-kt-sensor-10k-kit","status":"publish","type":"product","link":"https:\/\/profixtips.com\/fr\/product\/midea-kt-sensor-10k-kit\/","title":{"rendered":"Capteur de temp\u00e9rature ambiante et tubulaire 10K+10K pour climatiseur split - R\u00e9paration des erreurs Midea"},"content":{"rendered":"<p>Titre : Capteur de temp\u00e9rature ambiante et de tube 10K+10K pour climatiseur split Midea, correction d'erreur<\/p>\n<div>\n\t\t<span style=\"font-size:14pt;\"><br \/>\n\t\t<meta name=\"viewport\" content=\"width=750,user-scalable=yes\"><br \/>\n\t\t<\/span>\n\t<\/div>\n<h2>\n\t\t<span style=\"font-size:14pt;\"><strong>Universal 10K\u00a0<\/strong><\/span>Room Temperature Sensor<span style=\"font-size:14pt;\"><strong><br \/>\n+10K\u00a0<\/strong><\/span>Capteur de temp\u00e9rature de tube pour Midea\u00a0<strong style=\"font-size:14pt;\">Split Air Conditioner Err Fix\u00a0<\/strong><strong style=\"font-size:14pt;\">R\u00e9paration<\/strong><br \/>\n\t<\/h2>\n<p>\n\t\t\u00a0\n\t<\/p>\n<div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"color:red;font-size:14pt;\">Pour climatiseur split Midea<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div>\n\t\t\t<span style=\"font-size:14pt;\">Pin\u2019s Width: About 6 mm<\/span>\n\t\t<\/div>\n<div>\n\t\t\t<span style=\"font-size:14pt;\">Cord Length: About 34\u00a0cm \/ 53\u00a0cm<\/span>\n\t\t<\/div>\n<div>\n\t\t\t<span style=\"font-size:14pt;\">Sensor Probe\u2019s Resistance: 10K \/ 10K<\/span>\n\t\t<\/div>\n<\/p><\/div>\n<p>\n\t\t<span style=\"font-size:14pt;\">Poids : environ 20 g<\/span>\n\t<\/p>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t<span style=\"font-size:14pt;\"><span style=\"color:red;\">Si la fiche est diff\u00e9rente de celle de votre ancien capteur, vous pouvez d\u00e9monter ou couper les fiches ancienne et nouvelle, puis les reassembler pour les utiliser<\/span>\u00a0<\/span>\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<p>\n\t\t<span style=\"font-size:14pt;\">Veuillez v\u00e9rifier dans les sp\u00e9cifications de l'annonce si cet article est compatible avec votre appareil avant de passer commande.<\/span>\n\t<\/p>\n<p>\n\t\t<span style=\"font-size:14pt;\">Si vous avez des questions, n'h\u00e9sitez pas \u00e0 nous contacter avant votre achat. Merci !<\/span>\n\t<\/p>\n<div>\n\t\t<span style=\"font-size:14pt;\"><strong><span style=\"color:red;\">Nous avons \u00e9galement d'autres types de capteurs.<\/span><span style=\"color:red;\"><\/p>\n<p><\/span><\/strong><\/span>\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t<span style=\"font-size:14pt;\"><strong> Contenu du colis :<\/p>\n<p><\/strong><\/span>\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t<span style=\"font-size:14pt;\">1x Capteur de temp\u00e9rature universel<\/span>\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t<span style=\"font-size:14pt;\">\u2014-( Type al\u00e9atoire envoy\u00e9 )\u00a0<\/span>\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t<span style=\"font-size:14pt;\"><strong style=\"color:red;\">\u00a0Reconnaissance des capteurs de temp\u00e9rature de climatiseur<\/strong><\/span>\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">G\u00e9n\u00e9ralement, 5K\u201310K est utilis\u00e9 pour les machines murales, et 10K\u201320K pour les mod\u00e8les gain\u00e9s. Concr\u00e8tement, vous devez utiliser votre propre multim\u00e8tre pour mesurer la r\u00e9sistance.<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">Le capteur de temp\u00e9rature ambiante g\u00e9n\u00e9ral est un petit composant situ\u00e9 pr\u00e8s des ailettes sur la face noire de l'unit\u00e9 ext\u00e9rieure contre le mur. Le capteur de temp\u00e9rature du tube est ins\u00e9r\u00e9 dans la paroi du serpentin \u00e0 l'int\u00e9rieur de l'unit\u00e9 ext\u00e9rieure.<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">La t\u00eate en cuivre d\u00e9tecte les tubes cuivr\u00e9s avec rapidit\u00e9. La t\u00eate en plastique sert g\u00e9n\u00e9ralement \u00e0 mesurer la temp\u00e9rature ambiante, avec r\u00e9sistance \u00e0 la corrosion et fiabilit\u00e9 \u00e9lev\u00e9e.<\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\"><strong>Comment d\u00e9terminer la r\u00e9sistance d'un capteur de temp\u00e9rature de climatiseur<\/strong><\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">Les concepteurs de circuits utilisent 25\u00b0C comme r\u00e9f\u00e9rence : \u00e0 25\u00b0C, RT1=R1, RT2=R2, et les tensions aux points A\/B sont de 2,5V. Certains circuits incluent R3\/R4 comme tampons. Si la temp\u00e9rature augmente, la r\u00e9sistance RT1 diminue, la tension au point A monte, et le comparateur g\u00e9n\u00e8re une pression diff\u00e9rentielle d\u00e9clenchant les traitements CPU pour contr\u00f4ler les \u00e9tats op\u00e9rationnels.<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">Pour les climatiseurs inverter, la tension d'\u00e9chantillonnage VI n'est pas 2,5V mais 1,25V (1\/4 de l'alimentation). Une m\u00e9thode simple pour mesurer la r\u00e9sistance : utiliser un potentiom\u00e8tre 50k et une prise universelle. Apr\u00e8s branchement et alimentation, r\u00e9gler le potentiom\u00e8tre jusqu'\u00e0 obtenir 2,5V au multim\u00e8tre. La r\u00e9sistance affich\u00e9e correspond \u00e0 celle du capteur (ex : 8k \u00e0 30\u00b0C indique un capteur 10k).<\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\"><strong>Comment \u00e9valuer la qualit\u00e9 d'un capteur de temp\u00e9rature de climatiseur<\/strong><\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">Sympt\u00f4mes d'un capteur d\u00e9fectueux :<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">1. R\u00e9sistance excessive du capteur ambiant \u2192 d\u00e9clenchements fr\u00e9quents<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">2. R\u00e9sistance r\u00e9duite du capteur de tube \u2192 arr\u00eat pr\u00e9matur\u00e9<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">3. Valeurs anormales des capteurs \u2192 dysfonctionnements<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">4. R\u00e9sistance nulle du capteur de tube \u2192 absence de r\u00e9action au d\u00e9marrage<\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\"><strong>Solution en cas de\u00a0<\/strong><strong>d\u00e9faillance du capteur :<\/strong><\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">Les capteurs repr\u00e9sentent une part importante des pannes. Un climatiseur standard comprend trois capteurs :<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">1. Capteur ambiant : contr\u00f4le la temp\u00e9rature int\u00e9rieure et g\u00e8re l'arr\u00eat des unit\u00e9s.<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">2. Capteur de tube int\u00e9rieur : surveille la temp\u00e9rature du serpentin (protection anti-gel\/surchauffe).<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">3. Capteur de d\u00e9givrage ext\u00e9rieur : si la r\u00e9sistance est trop \u00e9lev\u00e9e ou la temp\u00e9rature &lt; -6\u00b0C pendant 2 min, le d\u00e9givrage s&#039;active.<\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\"><strong>Causes d'une discordance temp\u00e9rature affich\u00e9e\/per\u00e7ue :<\/strong><\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">1. R\u00e9glage incorrect de la t\u00e9l\u00e9commande<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">2. Filtres encrass\u00e9s<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">3. Obstruction des entr\u00e9es\/sorties d'air, ou pr\u00e9sence de sources de chaleur\/personnes.<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">4. L'isolation de la pi\u00e8ce est m\u00e9diocre ;<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">5. La tension d'alimentation interne est trop basse, ce qui r\u00e9duit l'efficacit\u00e9 du climatiseur ;<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">6. La temp\u00e9rature ambiante est trop \u00e9lev\u00e9e ou trop basse, ce qui donne des r\u00e9sultats insatisfaisants.<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">Lors de la maintenance des climatiseurs, le capteur de temp\u00e9rature (thermistance) pr\u00e9sente une proportion \u00e9lev\u00e9e de pannes. En cas de d\u00e9faut tel qu'un circuit ouvert, un court-circuit ou une courbe caract\u00e9ristique d\u00e9grad\u00e9e, le climatiseur affiche un code anormal et ne peut fonctionner normalement. Comme le capteur de temp\u00e9rature n'indique pas les param\u00e8tres et les valeurs de r\u00e9sistance, il est souvent difficile \u00e0 diagnostiquer lors de la maintenance. M\u00eame pour une m\u00eame marque et des mod\u00e8les diff\u00e9rents, les valeurs de r\u00e9sistance ne sont pas n\u00e9cessairement identiques.<\/span>\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t<\/div>\n<div id=\"pastingspan1\">\n\t\t\t<span style=\"font-size:14pt;\">Le capteur de temp\u00e9rature voit sa r\u00e9sistance diminuer lorsque la temp\u00e9rature augmente ; la r\u00e9sistance augmente lorsque la temp\u00e9rature diminue.<\/span>\n\t\t<\/div>\n<div>\n\t\t\t<span style=\"font-size:14pt;\">La tension d'\u00e9chantillonnage de la borne n\u00e9gative du comparateur du CPU est 1\/2 de la tension d'alimentation du CPU, soit 2,5 V.<\/span>\n\t\t<\/div>\n<div>\n\t\t\t<span style=\"font-size:14pt;\">Les circuits p\u00e9riph\u00e9riques RT1 et RT2 ont des r\u00e9sistances de pull-up du c\u00f4t\u00e9 positif du comparateur, et R1 et R2 sont les r\u00e9sistances de polarisation inf\u00e9rieures.<\/span>\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<div>\n\t\t\t\u00a0\n\t\t<\/div>\n<\/p><\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n\t\t\u00a0\n\t<\/div>\n<div>\n<p>\n\t\t\t\u00a0\n\t\t<\/p>\n<\/p><\/div>","protected":false},"excerpt":{"rendered":"<p>Capteur de temp\u00e9rature ambiante et tubulaire 10K+10K pour climatiseur split - R\u00e9paration des erreurs Midea<\/p>","protected":false},"featured_media":1312,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[2],"product_tag":[28],"class_list":["post-1311","product","type-product","status-publish","has-post-thumbnail","product_cat-air-conditioner-parts","product_tag-air-conditioner-parts","product_shipping_class-free-shipping","first","instock","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/product\/1311","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/comments?post=1311"}],"version-history":[{"count":0,"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/product\/1311\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/media\/1312"}],"wp:attachment":[{"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/media?parent=1311"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1311"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1311"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/profixtips.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1311"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}