﻿{"id":4357,"date":"2025-05-03T20:43:58","date_gmt":"2025-05-03T12:43:58","guid":{"rendered":"https:\/\/profixtips.com\/product\/zykt-sensor\/"},"modified":"2025-05-31T02:49:57","modified_gmt":"2025-05-30T18:49:57","slug":"zykt-sensor","status":"publish","type":"product","link":"https:\/\/profixtips.com\/sl\/product\/zykt-sensor\/","title":{"rendered":"2m vrvica 5K\/10K\/50K senzor temperature za centralno klimatsko napravo za Daikin, Haier, Hitachi"},"content":{"rendered":"<p>Title: 2m Cord 5K\/10K\/50K Central Air Conditioner Temp Sensor For Daikin Haier Hitachi<\/p>\n<p>Opomba:<br \/>\nThe size and special specifications can be customized according to customer demand for 25\u2103=NTC, 5K, 10K, 15K, 20K, 50K (\u00b13).<br \/>\nCable Length About: 200 cm; Weight About 20 g.<\/p>\n<p>Pred oddajo naro\u010dila preverite v opisu izdelka, ali je ta kompatibilen z va\u0161o napravo.<\/p>\n<p>\u010ce imate kakr\u0161na koli vpra\u0161anja, nas pred nakupom kontaktirajte. Hvala!<\/p>\n<p>Na voljo so tudi drugi tipi senzorjev.<\/p>\n<p>Paket vsebuje:<\/p>\n<p>1x Universal Temperature Sensor<\/p>\n<p>\u2014-(naklju\u010dna vrsta bo poslana)<\/p>\n<p><!--PA4_HTMLTop_End--><\/p>\n<p><span style=\"font-size: 14pt;\"><strong>Universal 2m Cord 5K\/10K\/50K\u00a0Central Air Conditioner \/ Water\u00a0Heater\u00a0Temperature Sensor For Daikin Haier Hitachi etc.<\/strong><\/span><\/p>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">Opomba: <\/span><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">The size and special specifications can be customized according to customer demand for 25\u2103=NTC, 5K, 10K, 15K, 20K, 50K (\u00b13).<\/span><\/div>\n<div><\/div>\n<p><span style=\"font-size: 14pt;\">Cable\u00a0Length\u00a0About: 200 cm;\u00a0Weight About 20 g.<\/span><\/p>\n<div><\/div>\n<div><\/div>\n<p><span style=\"font-size: 14pt;\">Pred oddajo naro\u010dila preverite v opisu izdelka, ali je ta kompatibilen z va\u0161o napravo.<\/span><\/p>\n<p><span style=\"font-size: 14pt;\">\u010ce imate kakr\u0161na koli vpra\u0161anja, nas pred nakupom kontaktirajte. Hvala!<\/span><\/p>\n<div>\n<p><span style=\"font-size: 14pt;\"><strong><span style=\"color: red;\">We Also Have the\u00a0Other\u00a0Types\u00a0Sensors.<\/span><\/strong><\/span><\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<p><span style=\"font-size: 14pt;\"><strong> Paket vsebuje:<\/strong><\/span><\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<div><\/div>\n<div><span style=\"font-size: 14pt;\"> 1x Univerzalni Senzor Temperature<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-size: 14pt;\">\u2014-( Naklju\u010dna Vrsta bo Poslana )\u00a0<\/span><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><span style=\"font-size: 14pt;\"><strong style=\"color: red;\">\u00a0Acknowledges\u00a0Of The Air\u00a0Conditioner&#8217;s Temperature Sensor<\/strong><\/span><\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">Generally, 5K&#8211;10K is used for hanging machines, and 10K&#8212;20K is used for cabinets. Specifically, you need to use your own multimeter to measure the resistance.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">The general ambient temperature sensor is a small thing that is close to the fins in the black side of the outdoor unit against the wall. The temperature sense of the tube is inserted in the wall of the coil inside the outdoor unit.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">The copper head is used to detect copper tubes, and the temperature is fast. The plastic head is generally used to detect ambient temperature, corrosion resistance and high reliability.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\"><strong>How to judge the resistance of air conditioner temperature sensor<\/strong><\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">The air-conditioning circuit designer uses the normal temperature of 25 degrees as the reference, that is, when it is 25%, RTl=R1, RT2=R2, and the voltages of points A and B are 2.5V. Some circuits are equipped with R3 and R4, which mainly serve as a buffer. When the ambient temperature rises, the RTI resistance decreases, the voltage at point A rises, the comparator outputs a differential pressure, and a series of internal processing of the CPU controls the internal and external operating states.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">Large air conditioner, inverter air conditioner external control board, temperature sensor connected VI sampling voltage is not 2.5V, but 1\/4 power supply voltage, which is 1.25V, in fact, there is a method to determine the thermistor resistance is particularly simple, Choose a 50k potentiometer and a thermistor universal plug. For convenience, you can connect with long wires. Unplug the suspected thermistor, plug in the universal plug, energize the air conditioner, and test the potentiometer with the multimeter 5v. The voltage of the terminal slowly turns the potentiometer handle. When the voltage is 2.5V, the rotation stops. At this time, the resistance of the potentiometer is the resistance of the thermistor. For example, if the resistance is 8k and the ambient temperature is about 30\u00b0C, then the temperature sensor has a resistance of 10k.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\"><strong>How to judge the quality of the air conditioner temperature sensor<\/strong><\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">If the air conditioner temperature sensor is broken, the following phenomena will occur, and the air conditioner temperature sensor can be judged by this:<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">1. The indoor ring temperature sensor has a large resistance value, causing the air conditioner to start frequently.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">2. The resistance of the indoor tube temperature sensor becomes smaller, which causes the whole machine to be protected soon after starting.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">3. The indoor temperature and temperature of the pipe are changed, causing the air conditioner to malfunction.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">4. The indoor tube temperature change value is 0 \u03a9, which causes the whole machine to start remotely without reaction.<\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\"><strong>Solution When\u00a0<\/strong><strong>Air conditioning temperature sensor is bad:<\/strong><\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">The temperature sensor barrier has a relatively large proportion in air conditioning faults. To accurately determine the function, the air conditioning control section has three temperature sensors:<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">1. Room temperature sensor: mainly detects the indoor temperature. When the indoor temperature reaches the set requirement, the internal and external machines are controlled. When the cooling is stopped, the external machine stops, and the internal machine continues to run.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">2. Indoor tube temperature sensor: It mainly detects the coil temperature of the indoor evaporator, and prevents cold air, anti-overheat protection and temperature automatic control during heating.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">3. Outdoor defrosting temperature sensor: mainly detects the outdoor condenser coil temperature. When the outdoor coil temperature is lower than -6 degrees Celsius for 2 minutes, the internal machine turns into a defrosting state, when the outdoor coil sensor resistance is too large The indoor unit does not work properly.<\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\"><strong>Analysis of the reason why the air conditioner display temperature is inconsistent with the actual perceived temperature:<\/strong><\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">1. The remote control setting is incorrect;<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">2. The filter is not cleaned in time;<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">3. There are items in the air inlet and outlet of the air conditioner that affect the heating effect. The room has a heat source or many indoor personnel, resulting in poor cooling effect;<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">4. The room insulation effect is poor;<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">5. The indoor power supply voltage is too low, resulting in low efficiency of air conditioning;<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">6. The ambient temperature is too high or too low, resulting in poor results.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">During the air conditioning maintenance process, the temperature sensor (thermistor) has a high proportion of faults. If there is a fault such as open circuit, short circuit or poor characteristic curve, the air conditioner will display an abnormal code and cannot work normally. Since the temperature sensor does not indicate the parameters and resistance values, it is often difficult to determine during maintenance. It is the same brand and different models, and the resistance values \u200b\u200bare not necessarily the same.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-size: 14pt;\">The temperature sensor, that is, the resistance decreases as the temperature rises; the resistance increases as the temperature decreases. <\/span><\/div>\n<div><span style=\"font-size: 14pt;\">The negative terminal sampling voltage of the CPU comparator is 1\/2 of the CPU power supply voltage, which is 2.5V. <\/span><\/div>\n<div><span style=\"font-size: 14pt;\">The peripheral circuits RT1 and RT2 have pull-up resistors on the positive side of the comparator, and R1 and R2 are the lower bias resistors.<\/span><\/div>\n<div><\/div>\n<div><\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>","protected":false},"excerpt":{"rendered":"<p>2m vrvica 5K\/10K\/50K senzor temperature za centralno klimatsko napravo za Daikin, Haier, Hitachi<\/p>","protected":false},"featured_media":4358,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[2],"product_tag":[28],"class_list":["post-4357","product","type-product","status-publish","has-post-thumbnail","product_cat-air-conditioner-parts","product_tag-air-conditioner-parts","product_shipping_class-free-shipping","first","instock","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/product\/4357","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/comments?post=4357"}],"version-history":[{"count":0,"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/product\/4357\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/media\/4358"}],"wp:attachment":[{"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/media?parent=4357"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/product_brand?post=4357"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/product_cat?post=4357"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/profixtips.com\/sl\/wp-json\/wp\/v2\/product_tag?post=4357"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}