﻿{"id":2207,"date":"2025-05-03T19:39:02","date_gmt":"2025-05-03T11:39:02","guid":{"rendered":"https:\/\/profixtips.com\/product\/2sh_dry-filter-1213cm\/"},"modified":"2025-06-02T03:04:09","modified_gmt":"2025-06-01T19:04:09","slug":"check-valve-air-dry-filter","status":"publish","type":"product","link":"https:\/\/profixtips.com\/zh\/product\/check-valve-air-dry-filter\/","title":{"rendered":"2x \u7a7a\u8abf\u51b0\u7bb1\u4e7e\u71e5\u904e\u6ffe\u5668\u96f6\u4ef6\uff0c\u51b7\u51cd\u6ac3\u6b62\u56de\u95a5 12\/13cm"},"content":{"rendered":"<p>Title: 2x Air Conditioner Fridge Air Dry Filter Part Chest Freezer Check Valve 12\/13cm<\/p>\n<h1 style=\"font-size: 18pt;\">2x\/Lot Universal Copper Air Conditioner R600A Fridge Air Dry Filter Chest Freezer Check Valve 19 x 130 mm,Fridge 16 x 125 mm<\/h1>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\"><strong>\u53ea\u8981\u5916\u89c0\u76f8\u540c\u6216\u76f8\u4f3c\uff0c\u5373\u53ef\u7528\u65bc\u60a8\u7684\u8a2d\u5099\uff01<\/strong><\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">\u7522\u54c1\u4e0a\u7684\u6578\u5b57\u8207\u5b57\u5143\u7121\u5be6\u969b\u610f\u7fa9\uff0c\u50c5\u4f9b\u53c3\u8003\uff01<\/span><\/div>\n<div><\/div>\n<div><\/div>\n<div><span style=\"color: #ff0000;\"><strong><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14pt;\">Dry Filter-12cm &#8211;For\u00a0Fridge<\/span><\/strong><\/span><\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14pt;\">Dimensions: \u03c616 x 125 mm, 2 Terminal (Inner): \u03c6 2 mm , \u03c6 5 mm<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14pt; color: #00ff00;\"><strong>Dry Filter-13cm &#8211;For Chest Freezer<\/strong><\/span><\/div>\n<div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 14pt;\">Dimensions: \u03c619 x 130 mm, 2 Terminal (Inner): \u03c6 2 mm , \u03c6 6 mm<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">Weight: about 60 g\/pcs, 80g\/pcs<\/span><\/div>\n<div><\/div>\n<div><\/div>\n<\/div>\n<div><span style=\"font-size: 12pt; font-family: arial, helvetica, sans-serif;\"><strong>\u5305\u88dd\u5167\u5bb9\uff1a<\/strong><\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\"><strong>2x Dry Filter-As your choice.<\/strong><\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\"><strong>\u2014-\uff08\u9810\u8a2d\u5c07\u96a8\u6a5f\u767c\u9001\u6279\u6b21 \/ \u984f\u8272 \/ \u985e\u578b\uff09<\/strong><\/span><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\"><strong>Symptoms of clogged filter:<\/strong><\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">1. The filter becomes cold, and the pipe from the liquid outlet to the solenoid valve will condense and frost.<\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">2. The cooling effect is poor, and the evaporator cannot be completely frosted.<\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">3. The suction pipe is not cold, the compressor temperature rises, the cylinder head does not feel hot or cold, and the exhaust pipe is hot.<\/span><\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\"><strong>What is the role of filter drier in refrigerator refrigeration system?<\/strong><\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">The filter drier is a device that has the dual functions of adsorbing moisture and filtering the refrigerant. Its function is to filter the tangible dust carried in the process of refrigerant flow and the residual moisture in the adsorption refrigeration system, so that the refrigerator refrigeration system does not have &#8220;dirty blockage&#8221; and &#8220;ice blockage&#8221; failures.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">The filter drier structure used in the refrigeration system of the refrigerator is equipped with a 120-200 mesh copper wire mesh inside and a desiccant is installed in the middle.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">A 120-mesh copper wire screen is installed at the inlet of the filter drier 1015mm to preliminarily filter the large particles of impurities entrained by the liquid refrigerant from the condenser, and one is installed at 1520mm from the outlet of the filter drier. The 200-mesh copper wire mesh is used to intercept the fine particles of impurities carried by the liquid refrigerant. In this way, the layered interception and filtration can basically filter out the impurities carried in the refrigerant to ensure that the capillary is not dirty.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">The desiccant in the filter drier for refrigerators uses a substance called molecular sieve.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">Molecular sieve, also known as synthetic zeolite, is a kind of aluminosilicate with a crystalline framework structure. It is a white powder and is insoluble in water. The molecular sieve in the filter drier is generally molded into a small spherical shape with a binder. Its crystal gap is about 0.4nm, which can adsorb water molecules with a diameter of 0.170.38nm, and refrigerant molecules and frozen lubricants with a molecular diameter greater than 0.4nm Molecules cannot be adsorbed, so different molecular sieves can be used to screen substances of different diameters. This is why synthetic zeolite is called molecular sieves.<\/span><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">Each gram of molecular sieve can absorb 160-200mg of water. A dry filter contains about 10g of molecular sieve, which can generally absorb 1.6-2g of water.<\/span><\/div>\n<div><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\"><strong>Filter drier selection requirements: <\/strong><\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">The molecular diameter of the refrigerant is larger than the molecular diameter of the desiccant and the diameter of the water molecule. That is to say, the filter pore size of the molecular sieve desiccant is larger than the diameter of the water molecule, but smaller than the molecular diameter of the refrigerant and engine oil.<\/span><\/div>\n<div id=\"pastingspan1\"><span style=\"font-family: arial, helvetica, sans-serif; font-size: 12pt;\">Requirements of R134A: R134A is insoluble in mineral oil, it uses ester oil. Compared with R12 refrigerant, it is non-toxic, non-flammable and environmentally friendly. Thermal performance is close to r12. Disadvantages: Easy to absorb water, which requires higher water and system cleanliness. . It is required to choose XH-7 or XH-9 dry filter. While the conventional filter absorbs water, it also absorbs part of the 134A refrigerant molecules. Therefore, special desiccants must be used for freezers that use 134A refrigerant. The filter pore size of 134A refrigerant desiccant is smaller than that of R12. Moreover, in order to speed up the water absorption rate of the desiccant, the amount of desiccant used is increased by 30%-50%, so if you can only use the market general filter in the 134A system, it is recommended to increase the amount of desiccant in two series, and the success rate of treating ice blocking is higher! !<\/span><\/div>\n<p>&nbsp;<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>2x \u7a7a\u8abf\u51b0\u7bb1\u4e7e\u71e5\u904e\u6ffe\u5668\u96f6\u4ef6\uff0c\u51b7\u51cd\u6ac3\u6b62\u56de\u95a5 12\/13cm<\/p>","protected":false},"featured_media":2208,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[8],"product_tag":[29],"class_list":["post-2207","product","type-product","status-publish","has-post-thumbnail","product_cat-refrigerator-parts","product_tag-refrigerator-parts","product_shipping_class-free-shipping","first","instock","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/product\/2207","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/comments?post=2207"}],"version-history":[{"count":0,"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/product\/2207\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/media\/2208"}],"wp:attachment":[{"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/media?parent=2207"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/product_brand?post=2207"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/product_cat?post=2207"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/profixtips.com\/zh\/wp-json\/wp\/v2\/product_tag?post=2207"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}